ESound Med

ESound Med Disposable Protective Clothing

Features
•Made of protective non-woven fabrics.
•Excellent microbial barrier
•Excellent physical barrier to contaminants and fluids
•Stronger fabric with a matte surface, resistance to tear.
•Softer fabric with comfort inside and outside.
•Offering superior levels of protection to avoid the risk of cross infection.

Item
Details
Place of Origin
Changyuan, China
Brand Name
ESound Med
Model Number
coverall
Disinfecting Type
EO
Size
160-185
Type
Medical Protective Clothing
Stock
yes
Shelf Life
2 years
Quality Certification
ISO 13485
Safety standard
GB 19082-2009
Instrument classification
Class II
Material
SMMS SF
function
Applied to Provide Separation and Protection From the Blood, Body Fluid and Secretions of the Potential Infectious Patients For Clinical Medical Staff At Work
Logo
ESound Med or Customized
Material
SMS/ SMMS/ PP+PE /PP+SF
packing
1 piece/bag, 20 pcs/ctn
MOQ
20 pieces
Delivery time
8-15 days

 

[Product]: Medical Protective Clothing [Specifications]: 160, 165, 170, 175, 180, 185
[Production License Number]: No. 20160050 of Henan Food and Drug Administration Production License
[Registration Number]: Henan Medical Device 20182140613
[Product Technical Requirement Number]: Henan Medical Device 20182140613
[Range of Application]: Applied to Provide Separation and Protection From the Blood, Body Fluid and Secretions of the Potential Infectious Patients For Clinical Medical Staff At Work
[Structure and Composition]: This Product Is Made of Nonwoven Fabrics, Sewed, Glued and Heat Sealed By Machine.
[Product Performance]:
1. The Protective Clothing Should Be Dry, Clean and Spotless Without Adhesion, Gap or Holes; Connecting Parts Can Be Joined By Processing Methods Such As Sewing, Gluing, Heat Sealing And So On. Marks of Sewing Should Be Sealed Up. There Should Be 8-14 Stitches Every 3cm. Marks of Sewing Should Be Even And Straight In A Row. The Parts Processed by Gluing, Heat Sealing etc. Should Be Smooth, Sealed With No Bubbles; For Protective Clothing Equipped With A Zip, The Zip Should Not Be Exposed and The Slide Should Be Able to Zip Up Spontaneously.
2. Medical Protective Clothing Consists of Tops with A Hood and Pants. Tops and Pants Can Be Joined Together or Separated; The Design of The Protective Clothing Should Be Suitable. It Should Be Easy to Put On and Take Off. The Connecting Parts Should Be Sealed Up Tightly; Sleeves and Leg Openings Should Be Able to Close Up Elastically. The Front Face of the Hood and the Waistband Should Be Able to Close Up Elastically or with Pull Cords or With Cottons.
3. It Should Meet Up the Requirements in Sheet 1 and Sheet 2 of GB19082-2009.
4. Fluid Resistance
4.1 Water Resistance: Hydrostatic Pressure of The Key Parts of The Medical Protective Clothing Should be Higher Than 1.67kPa (17cmH2O).
4.2 Moisture Permeability of The Medical Protective Clothing Should be Higher Than 2500g/(㎡•d)
4.3 Compound Blood Anti-Penetration: Compound Blood Penetration of The Medical Protective Clothing Should be Higher Than the Requirements of Level 2 in Sheet 3 of GB19082-2009.
4.4 Water Resistance: The Waterproof Level of the Outer Sides of The Medical Protective Clothing Should be Higher Than the Requirements in Level 3.
5. The Tensile Strength of the Key Parts of The Medical Protective Clothing Should Be Bigger Than 45N.
6. The Percentage of Breaking Elongation of the Key Parts of The Medical Protective Clothing Should Be No Smaller Than 15%.
7. The Filtration Efficiency for Non-Oily Particles of the Key Parts and the Joints of The Medical Protective Clothing Should Be No Lower Than 70%.
8. Quantity of Electric Charge That The Medical Protective Clothing Carries Should Be No Bigger Than 0.6μC/Piece.
9. The Static Electricity Attenuation of The Medical Protective Clothing Should Be No Longer Than 0.5s.
10. The Medical Protective Clothing Should Be Sterile.
11. After the Ethylene Oxide Sterilization, The Residual Ethylene Oxide Should Be No More Than 10μg/g.
[Instructions]:
1. Check If There is Any Damage of the Package. Do Not Use If the Package is Broken.
2. Take Out the Medical Protective Clothing and Put It On Properly.
[Storage Requirements]: Store in a Dry and Clean Warehouse with Excellent Ventilation and No Corrosive Gas Where the Relative Humidity is Less than 80%.
[Production Date]: On the Package.
[Date of Expiry]: On the Package.
[Contraindications]: Not Found Yet.
[Caution]:
1. After Ethylene Oxide Sterilization, the Sterility Remains Valid for Two Years.
2. Production Date and Date of Expiry are Printed on the Package. The Date of Sterilization Is Printed on the Outer Package Box.
3. It is Forbidden to Use Products Out Of the Validity Period of Sterility.
4. Do Not Use If the Package is Damaged.
5. This Product is Disposable. Dispose After Use.
[Term of Validity]: 2 Years (Printed on the Package and Box).

Disposable Aseptic Ethylene Oxide Sterilization Caution

[Registrant Name]: ESound Medical Device Co., Ltd.
[Address]: High-Tech Medical Device Industrial Park, Changyuan County
[Contact]: 0373-7152666
[After-Sales Service Unit]: ESound Medical Device Co., Ltd.
[Registrant Organization]: ESound Medical Device Co., Ltd.
[Address]: High-Tech Medical Device Industrial Park, Changyuan County
[Production Address]: High-Tech Medical Device Industrial Park, Changyuan County
[Contact]: 0373-7152666
[Date of Compilation]: November 1, 2019

size